The Macylab ICP-6800E is a direct-reading Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) professionally designed for the analysis and determination of rare earth elements. It is specifically engineered to measure 15 lanthanide series elements alongside Scandium (Sc) and Yttrium (Y), providing a total of 17 target elements for rare earth composition analysis.
Operating with a 1000mm focal length Czerny-Turner optical system and an imported Photomultiplier Tube (PMT) detector, the instrument provides the high spectral resolution necessary to separate the complex emission lines typical of rare earth matrices. It analyzes liquid samples dissolved in common acids, including nitric acid, hydrochloric acid, and hydrofluoric acid.
Key Features
Dedicated Rare Earth Focus: Designed for the composition analysis of rare earth ores, as well as the quality examination of raw materials and finished products containing lanthanide elements.
Solid-State RF Power Supply: Features an automatic matching function operating at a frequency of 27.12MHz. The power output is adjustable between 500W and 1600W, maintaining a strict output stability of <0.3% to ensure consistent plasma generation.
Czerny-Turner Optical System: Utilizes a 1000mm focal length optical bench equipped with an ion beam etching holographic grating. The system can be configured with a 3600 lines/mm grating to maximize resolution or a 2400 lines/mm grating to extend the wavelength range.
Photomultiplier Tube (PMT) Detector: Integrates high-performance R293 or R928 PMT detectors driven by a stable negative high voltage supply (0-1000V, stability <0.05%), ensuring reliable photoelectric conversion of emission signals.
Precision Sampling System: Includes a three-concentric torque tube (20mm external diameter), a 6mm coaxial nebulizer, and a 34mm double barrel atomizing chamber to support efficient sample introduction.
Specifications
Parameter
Specification
Model
ICP-6800E
Circuit Type (RF)
Solid-state RF power supply, auto-match function
RF Frequency
27.12MHz ±0.05%
Power Output
500 — 1600W
Power Output Stability
< 0.3%
Escaped RF Radiation
E < 2V/m (at 30cm from the instrument)
Optics
Czerny-Turner type
Focal Length
1000 mm
Grating Options
Ion Beam Etching Holographic, 3600 L/mm or 2400 L/mm
The ICP-6800E is optimized for environments that process complex inorganic materials and minerals:
Rare Earth Ore Analysis: Determining the elemental composition of extracted rare earth minerals, focusing on lanthanides, Scandium, and Yttrium.
Material Quality Control: Examining the purity and elemental composition of rare earth raw materials and related finished products.
Geological and Soil Testing: Analyzing trace elements in rock and soil extracts dissolved in strong acids, including hydrofluoric acid.
Metallurgical Industry: Routine testing of metal alloys and magnetic materials that utilize specific rare earth additives for performance enhancement.
Who is it for?
Rare Earth Processing Facilities: QC laboratories in mining and metallurgical plants that require dedicated, reliable determination of lanthanide elements to assess material purity.
Geological and Research Institutes: Academic and commercial laboratories conducting detailed composition analysis of complex ores and geological matrices.
Comprehensive Analytical Labs: Facilities requiring a PMT-based ICP-OES with extremely high optical resolution (up to ≤0.007nm) to avoid spectral overlaps characteristic of rare earth elements.
Why choose it?
High-Resolution Capability: Rare earth elements produce highly complex emission spectra with many closely spaced lines. By utilizing the 3600 lines/mm grating, the instrument achieves a resolution of ≤0.007nm, which is crucial for reducing spectral interference during lanthanide analysis.
Targeted Analytical Solution: The instrument is professionally configured to handle the specific requirements of rare earth testing, supporting limits of detection suitable for industrial quality control.
Certified Qualifications: The instrument complies with major international product qualifications and safety standards, holding certifications including the European CE mark, North American ETL, FCC, RoHS, China CQC, and 3C.
Packaging, Installation & Operation
Packaging & Shipping
After unpacking the instrument, compare the contents with the packing list and check that all items are present and undamaged.
Installation & Setup
Place the spectrophotometer in a suitable location away from direct sunlight, dust, corrosive gases, and strong vibrations. For stable operation, keep it away from strong magnetic or electrical fields and electrical devices that may generate high-frequency fields.
Keep the area around and underneath the instrument clear to allow adequate airflow.
Use the appropriate power cord and connect the instrument to a grounded outlet.
Initial Operation
Turn on the spectrophotometer and allow it to warm up for the recommended time before taking measurements. Follow the instrument’s operating instructions to complete any required system initialization, calibration, or wavelength verification before measurement.
Exhibition
FAQ (Frequently Asked Questions)
The instrument is designed to determine 17 specific elements: 15 lanthanide series elements (La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) as well as Scandium (Sc) and Yttrium (Y).
The wavelength range depends on the installed grating. With the 3600 lines/mm grating, the range is 190nm to 500nm. With the 2400 lines/mm grating, the range expands from 190nm to 800nm.
The ICP-6800E utilizes an imported Photomultiplier Tube (PMT) detector (specifications R293 or R928), providing stable photoelectric conversion of the specific emission wavelengths.
Yes, the solid-state RF generator and the working coil require a continuous cooling water supply. The specifications require a water temperature of 20-25℃, a flow rate greater than 5L/min, and a hydraulic pressure greater than 0.1MPa.
Yes. The instrument is designed to analyze substances dissolved in various harsh acid matrices, including nitric acid, hydrochloric acid, and hydrofluoric acid.