Key Features

  • Solid-State RF Power Supply: Features an automatic matching function operating at a frequency of 27.12MHz. It provides an adjustable power output between 500W and 1600W, maintaining a strict power output stability of <0.3%.
  • Czerny-Turner Optical System: Utilizes a 1000mm focal length optical bench equipped with an ion beam etching holographic grating. Users can configure the system with either a 3600 lines/mm or 2400 lines/mm grating based on specific analytical requirements.
  • Photomultiplier Tube (PMT) Detector: Integrates high-performance R293 or R928 PMT detectors with a stable negative high voltage supply (0-1000V, stability <0.05%), ensuring consistent photoelectric conversion of the emission signals.
  • Precision Sampling System: Includes a three-concentric torque tube (20mm external diameter), a 6mm coaxial nebulizer, and a 34mm double barrel atomizing chamber to support efficient sample introduction and aerosol generation.
  • Controlled Gas Flow: Carrier, plasma, and auxiliary Argon gas flows are regulated through dedicated flowmeters, accompanied by a 0-0.4MPa pressure maintaining valve for stable plasma operation.

Specifications

ParameterSpecification
ModelICP-6800S
Circuit Type (RF)Solid-state RF power supply, auto-match function
RF Frequency27.12MHz ±0.05%
Power Output500 — 1600W
Power Output Stability< 0.3%
Escaped RF RadiationE < 2V/m (at 30cm from the instrument)
OpticsCzerny-Turner type
Focal Length1000 mm
Grating OptionsIon Beam Etching Holographic, 3600 L/mm or 2400 L/mm
Wavelength Range190nm – 500nm (3600 L/mm) | 190nm – 800nm (2400 L/mm)
Resolution≤ 0.007nm (3600 L/mm) | ≤ 0.015nm (2400 L/mm)
Reciprocal Linear Dispersion0.26 nm/mm
Stepping Motor Pace≤ 0.0006 nm
DetectorPhotomultiplier tube (R293 / R928)
PMT Negative HV0-1000V (Stability <0.05%)
Cooling Water Requirements20-25℃, Flow >5L/min, Pressure >0.1MPa

Applications

The ICP-6800S is utilized for trace elemental analysis in standard industrial and analytical fields:

  • Geological and Soil Testing: Analyzing elements in rock and soil extracts dissolved in strong acids (including hydrofluoric acid).
  • Metallurgy and Mining: Determination of trace impurities and elemental compositions in metallurgical materials.
  • Chemical Industry: Routine quality control testing of chemical raw materials and industrial manufacturing solutions.
  • Environmental Monitoring: Analyzing heavy metal contamination in water quality testing and environmental samples.

Who is it for?

  • Quality Control Laboratories: QC departments in chemical and metallurgical plants that require an established PMT-based ICP-OES for standard compliance testing.
  • Environmental Testing Agencies: Facilities focused on water and soil analysis that need to monitor trace elements reliably over time.
  • Research Institutions: Organizations that prefer the configurable resolution of a Czerny-Turner optical system combined with stable PMT detection.

Why choose it?

  • Configurable Optical Resolution: By offering two grating options, the instrument can be tailored to the lab’s specific needs. The 3600 lines/mm grating offers an exceptionally high resolution of ≤0.007nm for complex spectra, while the 2400 lines/mm grating extends the wavelength range up to 800nm.
  • Robust RF Stability: The solid-state RF power supply with an integrated auto-match function ensures consistent plasma ignition and operation, minimizing power fluctuations that could affect reading stability.
  • Certified Qualifications: The instrument complies with major international product qualifications and safety standards, holding certifications including the European CE mark, North American ETL, FCC, RoHS, China CQC, and 3C.

Packaging, Installation & Operation

Packaging & Shipping

After unpacking the instrument, compare the contents with the packing list and check that all items are present and undamaged.

Installation & Setup

Place the spectrophotometer in a suitable location away from direct sunlight, dust, corrosive gases, and strong vibrations. For stable operation, keep it away from strong magnetic or electrical fields and electrical devices that may generate high-frequency fields.

Keep the area around and underneath the instrument clear to allow adequate airflow.

Use the appropriate power cord and connect the instrument to a grounded outlet.

Initial Operation

Turn on the spectrophotometer and allow it to warm up for the recommended time before taking measurements. Follow the instrument’s operating instructions to complete any required system initialization, calibration, or wavelength verification before measurement.

products-Packaging-Shipping.

Exhibition

products-Exhibition.

FAQ (Frequently Asked Questions)

The wavelength range depends on the selected grating configuration. With the 3600 lines/mm grating, the range is 190nm to 500nm. With the 2400 lines/mm grating, the range extends from 190nm to 800nm.

Unlike CCD-based models, the ICP-6800S utilizes a Photomultiplier Tube (PMT) detector (specifications R293 or R928) to measure emission signals.

Yes, the RF generator and working coil require a cooling water supply. The specifications require a water temperature of 20-25℃, a flow rate of >5L/min, and a hydraulic pressure of >0.1MPa.

Yes. The instrument is designed to analyze substances dissolved in various matrices, including nitric acid, hydrochloric acid, and hydrofluoric acid.

The instrument relies on dedicated analog flowmeters. The plasma argon flow is adjustable from 100-1000 L/h, while both the auxiliary and carrier argon flows are adjustable from 10-100 L/h.

×