Product Description

A wide wavelength range, the wavelength range to meet the various requirements of the field.
Automatic design to achieve the most simple means of measurement.
LSI design greatly improves the stability and reliability of the system.
Improved optimization of the optical design, import source and receiver system created a high performance and high reliability.
Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three-wavelength (optional) DNA protein measurements (optional), and other measurement methods to meet different measurement requirements, and can be displayed directly on a 6-inch screen.
Based on user requirements optional hole rack, manual four with stand, manual Eighth rack, automatic Eighth frame,glass stand, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks.
Measurement data can be output through the printer with USB interface.
Can be powered down to save the measurement parameters and data, user-friendly.
Can achieve more accurate and flexible measurement via PC control, which can meet the needs of different users.

Product Specifications

Optical path structure Single beam spectrophotometer
Wavelength Range 190~1100nm
Band Width 1.0/2.0nm adjustable
Wavelength Accuracy ±0.3nm
Wavelength Repeatability 0.1nm
Photometric Accuracy ±0.2% τ
Photometric Repeatability 0.15% τ
Stray Light ≤0.03% τ
Stability 0.0005A/h@500nm
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -4~4A
Display Mode Touch LCD Screen (7 inches)
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Dimensions(W*D*H) 510×390×220mm
Weight 16Kg

Standard Configuration

m 2600

Software features

Wavelength Scan: the measured object can be 190nm-1100nm full band spectrum scan , can also be segmented scan
Kinetic tests: the time of the measured object scanning , timely detection of changes in concentration caused by changes in absorbance
Quantitative measurement: by establishing a standard curve , the concentration can be measured in the analysis was
Multi- wavelength testing : set a plurality of wavelengths simultaneously , the measured absorbance of a plurality of wavelengths in the test
DNA / protein test: the test formula purity of nucleic acid and protein concentration analysis of DNA / protein

DNA Protein

ul 1000
ul 1000

Kinetics

ul 1000
ul 1000

Multi Wavelength

ul 1000
ul 1000

Quantitive

ul 1000
ul 1000

WL Scan

ul 1000
ul 1000

Certifications

Product Qualification: European safety qualification mark CE, North American safety certification ETL, Federal Communications Commission FCC, European electrical safety certification RoHS, China Quality Certification Center CQC, China national mandatory product certification 3C

Packaging & Shipping

After carefully unpacking the contents, check the materials with the packing list (page 4) to ensure that you have received everything in good condition.

Place the instrument in a suitable location away from direct sunlight.  In order to have the best performance from your instrument, keep it as far as possible from any strong magnetic or electrical fields or any electrical device that may generate high-frequency fields. Set the unit up in an area that is free of dust, corrosive gases and strong vibrations.

Remove any obstructions or materials that could hinder the flow of air under and around the instrument.

Use the appropriate power cord and plug into a grounded outlet.

Turn on your spectrophotometer. Allow it to warm up for 15 minutes before taking any readings. We suggest you then do the Calibrate System with the Search 656.1nm to set the wavelength to the deuterium lamp emission line.